fullseye

日本語 · English · 简体中文 · 繁體中文 · 한국어 · Deutsch · हिन्दी · Français

Extras: more PoCs

This page also includes examples that are less polished than the exhibits on the main page. The figures for each exhibit come from its PoC run record.

Back to the main page

Try it yourself (more)

Details of the exhibits on the main page (full text)

What it can do

101 topics, each with an explanation page (how to use it, and its limits) and runnable examples.

Find

Measure

Light and colour

Waves and signals

Reconstruct and correct

Build a workflow

Show

Draw

All 189 usage examples that are not PoCs

See everything

285 PoCs plus 2 robot demos. Open a group to load its thumbnails.

Robot eyes (Fullseye does the perceiving) (2)
Industrial inspection (50)
Barcode tests must distinguish a wrong value from no value instead of counting returned answers alone. A simple code was degraded in four ways; strict reading gave a 7.3 % misread rate. A permissive reader appears more successful because it always returns digits, but creates far more wrong answers.1-D barcode Electrode tortuosity from CT — the rule of thumb only sees porosityElectrode tortuosity Bearing diagnosis needs a limit for finding fault impacts inside noise. A known impulse train was buried until the amplitude trace still detected every trial at -18.4 dB SNR. This processing reaches deeper than raw frequencies, but produces false alarms unless its cutoff comes from fault-free records.Bearing diagnosis Warpage removal can absorb a genuinely low bump into the correction surface. Curves fitted to a seeded pillar field left a 1.23 µm readout error after quadratic correction. Raising the order does not help, and a broad low-order defect vanishes into reported warpage while missed bumps increase.Bump coplanarity Real cracks are re-imaged with coarser pixels to compare thresholding with the integrated deficit. Across 159 public photos the typical width ratio stays closer to one for integration, but the quartiles overlap. Real crack cores are grey, so thresholding inflates thin cracks instead of losing them.Crack width Real fabric defects are scored against the supplied masks to compare textbook detectors for weave flaws. Counting only the core of the wide masks raises the same detector to an AUC of 0.66. Removing low frequencies erases painted mura, but on real defects the drop is much smaller.Fabric defects Digging Where the Sound Says — A Clean Correlation Still Digs in the Wrong PlaceLeak by sound Fusing thermal, vibration and geometry for machine health — three sensors, one factMachine health Reading a Binary Matrix Code — Geometry Always Dies FirstMatrix code Can Display-Inspection Moire (beat fringe between periodic patterns) Be Told From Real Non-Uniformity?Display moiré Print Misregistration from the Sheet — A Halftone Is a Lattice, So the Answer Is Not UniquePrint registration Rotating Real Textures — Rotation Invariance Holds Only Where It Is Not NeededRotating textures Sorting mixed waste by material — what a preprocessor can erase is decided by algebraWaste sorting Solder fillet AOI — three ring lights are a 3-level tilt quantiser, and 70 % of the fillet height sits in the darkSolder AOI Is the Process in Control, and Is It Capable? — Statistical Process Control from Closed-Form AloneSPC Every Sensor Reads Normal, Yet the Machine Is Failing — How Much the MT Method Recovers from Univariate 3σMT hidden fault Where Is the Text, Without a Recogniser — Grading a Stroke-Width Detector on Text We Drew OurselvesText regions How Much Camera Thermal Drift Costs a Dimensional MeasurementThermal drift A Thermal Image Is Not a Temperature Image — Emissivity, Reflection, and an Uncertainty That Does Not AddThermal radiometry In this synthetic experiment a flash warms the surface, and the cooling thermal images reveal how deep a delamination lies. The depth of small defects, far off with a long fit window, came back near the truth when the window was cut to 4 s. Too short a window fails on deep defects, so the window must follow the depth.Thermography NDT Veiling Glare Breaks Contrast Measurement — MTF (modulation transfer function) Passes While Black Level FailsVeiling glare Measuring a Camera Without Buying One — Recovering Quantum Efficiency, Gain and Dark Noise from a Planted Sensor with the EMVA 1288 (image-sensor characterization standard) ProcedureEMVA 1288 sensor In-Camera Processing Makes Datasheet Numbers Lie Plausibly - Denoising Adds 83 % to the Quantum Efficiency, the Standard's Check Misses It, Noise Correlation Catches ItIn-camera processing vs datasheets Naming the Damaged Roller from a Period — You Run Out of Evidence Before You Reach the CliffRoller defects A weld bead profile is read from the rows of a laser line. Filling the shadowed toe with 0 erased the undercut and the bead passed. Refusing to report unmeasured quantities stops that error, but the depth bias from speckle remains.Weld bead profile When a laser line traces a weld bead, a steeper camera angle measures height more finely. Even at 28 degrees, part of the undercut groove falls into its own shadow and its depth reads shallow. The shadowed span still looks measured, which makes the loss easy to miss.Weld bead scan Miscounting pores in a weld radiograph leads to the wrong weld grade. A fixed cut-off also counts the edge of the weld cap and reports 124 blobs. Estimating the background before detection keeps only real pores, and far fewer images are graded wrongly.Weld porosity Glyph typosGlyph typos Print Layer Inspection — Closing the Shape → Layer → Path → Image Loop and Catching Planted Defects by the NumbersPrint layers AGV fleet▶AGV fleet AM thermal to CT▶AM thermal to CT A symmetric part agrees with its own reflected or rotated copy when defect-free. After texture and illumination cancellation, mean residual in the defect region was 0.193. Robust centre estimation and rotational-order accuracy were checked as well.Self-referenced 2-D symmetry inspection Why a Thin Groove Vanishes in a PL Image — a Longer Diffusion Length Hides Only Shadow Grooves, and Makes Sink Grooves Stand OutPL groove vs diffusion length Counting Dense Bubbles — When the Overlap Is Too Deep to Decide, Return an Interval Instead of a Count▶Counting dense bubbles (an interval when undecidable) Grating Interferometry — Fibre Orientation, Micro-Cracks and Pores That Absorption Cannot See, Read From the Fringe Amplitude (Dark Field)Grating interferometry (fibres, cracks and pores in the dark field) In a food X-ray image, thick meat and a thin hard fragment can look the same. Counting photons by energy and separating thickness left at most 1 false lump on a synthetic tray across five photon-noise seeds. The material itself could not be read for a thin wire or under thick meat.Finding bone and glass in meat with two X-ray energies (dual-energy X-ray) Normalised cross-correlation, the usual template matcher, fails when part of the target is hidden or glare washes it out. Matchers comparing the sign of brightness changes were tested on 40 templates from public real photos. They withstand occlusion far better, yet every method stays weak to rotation.▶Code matching under light and occlusion Anomaly Detection from Good Samples Only — Classical Patch Features, a Per-Position Distribution Against a Memory Bank on One Yard-Stick, Down to a Recall-Guaranteeing ThresholdAnomaly detection from good samples only (classical patch features: distribution versus memory) Sorting multi-robot plans by how they braid▶Sorting multi-robot plans by how they braid Where the Maréchal approximation fails, by aberration shapeWhere the Maréchal approximation fails, by aberration shape Seven Mueller dimensions a four-angle polarisation camera cannot seeSeven Mueller dimensions a four-angle polarisation camera cannot see Slanted-edge SFR misreads MTF50 through gammaSlanted-edge SFR misreads MTF50 through gamma Raw Grey-Level Thresholds Need Retuning across Lighting, while k-Sigma and P-Tile TransferRaw grey-level thresholds need retuning across lighting, while k-sigma and P-tile transfer No Single Exposure Shows Both Scratches on Glossy Metal; HDR with a Measured Response DoesNo Single Exposure Shows Both Scratches on Glossy Metal; HDR with a Measured Response Does A Barcode Still Read 90 % of the Time at This Blur Grades F for Print QualityA Barcode Still Read 90 % of the Time at This Blur Grades F for Print Quality zxing-cpp Reads a Dot-Peen Data Matrix Only Once It Is Blurredzxing-cpp Reads a Dot-Peen Data Matrix Only Once It Is Blurred Past the Blur It Was Trained On, Lot-Number OCR Misreads Instead of RejectingPast the Blur It Was Trained On, Lot-Number OCR Misreads Instead of Rejecting Reading a 1943 Typewritten Report with Classical OCR — Four Classifiers Reach 96.6-98.1 % on Lines Segmented Correctly (95.4-97.1 % End to End), and a Dictionary Breaks Correct Words Unless the Vocabulary Is ClosedReading a 1943 typewritten report with classical OCR Voids in a synthetic aluminium casting were scanned with cone-beam CT and rebuilt by several methods. With 12 views, the method last by image error sized the voids best when volume is counted as missing material. Cutting the image at half density flips that order, so the result rests on the measure and a coarse grid.CT of Casting Voids: The RMSE Winner Lost on Void Volume Measured by Deficit (32³ synthetic; binarised volume reverses it) Synthetic ground-metal patches carry scratches, dents and stains, and learned models sort them. Only 0.324 of the scratches lying along the lay were found, and the cause is not identified. A single-feature outlier check rejected unseen pits more often than the learned density model did.Sorting Metal Surface Defects with Trained Classifiers: Scratches Along the Grinding Lay Are Missed 3 Times in 4, and Unseen Pits Are 95 % Rejected
Dimensional and shape metrology (55)
Full visual inspection and sampled CT must assign the same index to each joint. Unequal-sided fiducials fixed this correspondence, then top-ranked candidates caught 19 % of interface-touching voids. Apparent void rankings can agree while most life-limiting parts are missed.AOI-to-CT matching Point-cloud dimensions can confuse room heading or furniture with wall position. A room with known tilt and bulges was rotated, while its plane-pair error stayed at +2.24 mm. Bounding boxes grow with heading and sample count; plane fitting jumps to furniture when outliers become the majority.As-built walls Slight electrode growth must be separated from brightness changes between scans. Layer boundaries were tracked across two cross-sections, recovering a stack increase of +2.136 µm. A fixed brightness crossing reports false strain after an offset, whereas the gradient peak remains at zero.Electrode breathing A reference plane for left-right asymmetry may be pulled toward a one-sided deformation. A known bulge was added to a symmetric skull; the best-fit plane moved by 2.92 mm. The optimized plane shifts toward the bulge and removes part of the asymmetry that should be reported.Bilateral asymmetry DIC strain▶DIC strain Die tilt and TSV overlay from one CT — tilt fakes rotation tooDie tilt and TSV Dimensional Inspection of a Machined Part — Bias and Scatter as Two NumbersDimensional check Fibre Orientation Distribution — Angles Repeat Every 180 Degrees, and a Naive Mean Is 90 Degrees OffFibre orientation Gear Tooth Metrology — Eccentricity Is Order 1, Teeth Are Order zGear teeth Gaps are cut into hand-traced real grain boundaries to see where the two counting methods drift by a full step. The intercept count holds until 33.1 % of the traced lines are gone, far longer than the planimetric count. Image processing that expects dark boundaries finds almost none of them on tint-etched photos.Grain size Multibeam sonar▶Multibeam sonar Particle Size Distribution From Images — Merging and Edge Cuts Pull Opposite Ways and CancelParticle sizing Counting clipped or overlapping objects as one changes a microscopy size distribution. Synthetic truth shows a largest error of 0.165 px. Acceptance reasons and three bases remain with calibration provenance.Microscopy particle sizing After rotation stops, particles and bubbles keep moving while scratches remain still. The pooled independent holdout has a ninety-percent detection diameter of 164.20 µm. Back and side illumination place planted truth, matched tracks and a miss-side case in one view.Vial particle inspection after spin stop Measuring Rail with a Chord — At the Wavelengths Where the Transfer Function Is Zero, Any Amplitude Reads ZeroRail corrugation Counting and Measuring Real Coins — A Correct Answer Is Not a Safe OneReal coins Pitch, Flank Angle and Pitch Diameter From a Thread Silhouette — Tilt Shows Up With Opposite Signs on the Two FlanksScrew threads Stockpile volume▶Stockpile volume Creep strain▶Creep strain How Far Sa / Sq / Sz Survive Sampling and CutoffSurface roughness Tactile sensor▶Tactile sensor Tactile shear▶Tactile shear Tactile dipole▶Tactile dipole Powder heap▶Powder heap Food cutting▶Food cutting Soft dome contact▶Soft dome contact Polish and wipe▶Polish and wipe Powder scoop/pour▶Powder scoop/pour Mortar grinding▶Mortar grinding PXRD phases▶PXRD phases How Long to Grind for a Uniform Dose — Content Uniformity from Particle Size by Closed Form and Monte Carlo, Inverted through Comminution Laws; the Low CV from Photos Was the Same 12 Images at Different ScalesDose uniformity Tactile knife▶Tactile knife How Much of That Number Is Your Measuring - Gauge R&R (gauge repeatability and reproducibility) and Measurement Uncertainty▶Gauge R&R The Resolution Formula Does Not Tell You What You Will Find - Probability of Detection per Lighting (MIL-HDBK-1823A)POD per lighting When a laser line measures height, speckle, the grainy pattern of interfering light, breaks up the line. Reading position by the centroid still leaves an error of 6.4 µm, close to the floor the formula predicts. Averaging frames of a static part does not help; only moving the part lowers it.Speckle floor of a laser line Measuring Black-Gloss and Glass from Polarisation - No Shading, but the Polarisation Remembers the SlopeShape from polarisation Fringe Projection Misreads Even a White Groove - Separating the Interreflection, Predicting the Error Before Measuring, and Removing It with Micro Phase ShiftingInterreflection and fringe error Scoring an Aberration as a Picture: Zernike Polynomials (orthogonal aberration polynomials on a circular pupil) and the Point Spread Function▶Zernike aberrations Every Speedup Is the Same Arithmetic Regrouped: Scoring Attention with IdentitiesAttention identities Angles and Shifts No Single Phase Can Pin Down, Fixed by Bundling Phases of Different Periods — the Chinese Remainder Theorem in Images▶Phase CRT How Much the Bright SEM Edge Inflates a Dimension — the Shape Matches but the Area GrowsSEM edge inflation Chromatic Confocal Displacement Sensor — A Rainbow Ruler from Glass Dispersion, Reading Height from the Colour that Comes Back▶Chromatic confocal sensor (reading height from colour) In meetings about inspection systems, the lens layout and the setup drawing are the common language. The optical calculation now draws them directly, up to ISO 10110 element drawings. Each written file is read back, and its lines and text are scored against the calculation.Optical drawings from the calculation Counting Interreflection in a Machined Pocket to Convergence — The Direct-Light Model Fits with Albedo 1.32, the Converged Model Returns the TruthPocket interreflection to convergence Non-Coaxial Optics — a Coaxial-Illumination Beamsplitter Paints a False Defect on a Mirror-Like Part, Removed by a Coating or a Wedge; Fold Mirrors Shrink the MachineNon-coaxial optics: beamsplitter ghosts and folds Per-Pixel Quadrature Demodulation (Lock-in) — Ring-Illumination Normals, Coded-Light Daylighting and Lock-in Thermography, Scored Against Closed Forms and the Rice Phase DistributionPer-pixel lock-in demodulation: ring-light normals, daylighting, thermal waves Spectrometer and Illumination Trains — Where the Bandwidth Comes From, and Whether the Lamp Shows in the FieldSpectrometer and illumination (bandwidth and lamp structure) An imaging model was fitted to a published real image of a tilted alignment plate seen through a telecentric lens. The magnification came out at 252.14 px/mm, close to the paper's value. Places where the model does not fit are kept and drawn as residual needles on the image.Calibrating an imaging model on a real telecentric image Deep Scratches Dent the Mean Line — How Much Contamination Robust Gaussian and Spline Filters SurviveHow far a scratch dents the mean line, and where robust filters break The same nanoparticles are sized in both a scanning and a transmission electron image. Even for a 52 nm particle, the reading moved by nanometres with the imaging mode and cut-off level. Scored against a shared truth, both biases follow simple formulas for edge blur and defocus.▶The same particles in scanning and transmission images Measuring Tracks and Vias in a Real IC SEM Image — Does the Virtual-SEM Edge Correction Transfer?Metrology on real SEM metal layers Acceptance-Test an Optical 3-D Sensor Before Buying It: One Black Sphere Fails the Same iToFAcceptance-Test an Optical 3-D Sensor Before Buying It: One Black Sphere Fails the Same iToF Light-Section Heights Agree to Microns, but the Real Limit Is a 20.7 µm Speckle FloorLight-Section Heights Agree to Microns, but the Real Limit Is a 20.7 µm Speckle Floor Reading Real Scientific Data Files in Five Formats — Scored Against Independent Readers and Published Values, and One Reader Bug FixedReading real scientific data files Grain Boundaries from the Skeleton by Zones of Influence on Real Metallography — A Failure Report: Per-Image Grain Size Does Not Even Rank Correctly (rho -0.17), and Boundary Placement Loses to WatershedGrain boundaries from zones of influence
3-D shape (18)
Geometry and calibration (26)
Image quality and restoration (24)
Colour and separation (14)
Time as 3-D (22)
Connectome and neurons (20)
Medical and biological (9)
Astronomy and environment (22)
Forensics and documents (5)
Autonomous driving (13)
Mathematical pictures (7)

Figure licences (share-alike)

What you see, and the measured number

Every number is measured against ground truth the PoC planted itself (closed form, analytic solution or published value); running the PoC prints the same value.

Inspection and appearance

3-D measurement and geometry

X-ray CT and volumes

Optics, interferometry, polarization

Robotics and spatial perception

Humanoid robots

Autonomous driving

Robot eyes (Fullseye does the perceiving)

Back to the main page