fullseye

order_spectrum — ACOUSTICS order op

使い方

Amplitude against shaft order — the spectrum a run-up should be read in.

:func:angular_resample followed by an rFFT over a whole number of revolutions (the record is cropped to that). Bin spacing is 1 / whole_revolutions in orders.

revolutions overrides how many whole revolutions to keep, and it matters more than it looks. An order o lands exactly on a bin only when o * revolutions is an integer; otherwise it straddles two and both read low. Measured on the run-up below, which happens to cover 79.994 revolutions:

============== ========== ============= ============= revolutions resolution amp at o=1.0 amp at o=3.5 ============== ========== ============= ============= 79 (default) 0.012658 0.999967 0.636961 78 (even) 0.012821 1.000009 0.999371 ============== ========== ============= =============

That 0.637 is the classic two-bin scallop loss, and nothing raises: the peak is at the right order and 36 % too small, with a second peak of almost equal height one bin away (measured 0.6370 at order 3.4937 and 0.6353 at 3.5063). Cropping to an even number of revolutions puts every half-integer order on a bin. The default is the largest whole number available; pass revolutions when the order you care about is fractional.

Returns a dict: orders, magnitude (single-sided, 2/N), peak_order, peak_amplitude, peak_orders / peak_amplitudes, resolution_order, whole_revolutions, samples_per_rev, mean_rpm, max_order.

Measured, and this is the whole argument for the operator. A 4 s run-up from 600 to 1800 rpm at 5 kHz carrying exactly two shaft-locked components (orders 1.0 and 3.5, unit amplitude) plus one fixed 400 Hz resonance, read with revolutions=78:

========================== ===================== ==================== quantity ordinary spectrum order spectrum ========================== ===================== ==================== order-3.5 peak amplitude 0.070203 (of true 1) 0.999371 (of true 1) its -3 dB width 66.50 Hz (= 3.33 ord) 0.00000 order 400 Hz resonance amplitude 1.0000, one bin 0.0517, over 26.7 ord ========================== ===================== ====================

The ordinary spectrum recovers 7 % of the shaft-locked component’s amplitude, because the energy is spread over 3.3 orders’ worth of bins; the order spectrum recovers 99.94 % of it in a single bin whose -3 dB width is one bin. The 400 Hz resonance goes the other way — sharp in hertz, smeared across 26.7 orders after resampling. That reversal is the diagnostic, and it is why both spectra are worth computing: what stays sharp under angular resampling turns with the shaft, and what stays sharp under ordinary transformation does not.

Raises ValueError: everything :func:angular_resample refuses (in particular the aliasing refusal), a revolutions larger than the record actually contains, and a max_order above the angular Nyquist samples_per_rev/2.