synth opなし → video(引数だけで決まる op —— 画像やデータの入力を取らない)import fullseye as fs; fs.ledger.vial_spin_stop_sequence(shape=(96, 72), *, n_frames=18, frame_interval_s=0.04, initial_omega_rad_s=10.0, decay_time_s=0.25, vial_radius_mm=10.0, liquid_height_mm=28.0, particle_diameter_um=80.0, particle_density_kg_m3=1450.0, particle_contrast=0.16, illumination='back', n_particles=1, n_bubbles=1, n_scratches=1, viscosity_pa_s=0.003, fluid_density_kg_m3=1000.0, pixel_size_um=280.0, noise_sigma=0.012, seed=0) (実装を直接呼ぶなら import vialops; vialops.vial_spin_stop_sequence(shape=(96, 72), *, n_frames=18, frame_interval_s=0.04, initial_omega_rad_s=10.0, decay_time_s=0.25, vial_radius_mm=10.0, liquid_height_mm=28.0, particle_diameter_um=80.0, particle_density_kg_m3=1450.0, particle_contrast=0.16, illumination='back', n_particles=1, n_bubbles=1, n_scratches=1, viscosity_pa_s=0.003, fluid_density_kg_m3=1000.0, pixel_size_um=280.0, noise_sigma=0.012, seed=0)、台帳から引くなら opspharma.get("vial_spin_stop_sequence"))fullseye.ledger.vial_spin_stop_sequence(...) は宣言 out 型 video の値だけを返す(本体は補助情報も返す)。捨てられた側が要るときは fullseye.ledger.vial_spin_stop_sequence.raw(...)、または vialops.vial_spin_stop_sequence を直接呼ぶ。回転停止後のバイアル画像列と物体ごとの真値軌跡を作る。
The liquid azimuthal velocity is the axisymmetric, prescribed field
u_theta(r,t) = omega0 exp(-t/tau) r; it is not a Navier–Stokes
solution. A particle has that in-plane advection plus its Stokes terminal
velocity v_t = 2 r_p^2 (rho_p-rho_f) g / (9 mu) in the image-downward
direction. Bubbles use rho_p=1.2 kg/m^3 and therefore rise. The model
is restricted to small Reynolds number / isolated spherical objects where
Stokes drag is appropriate; it does not model turbulent wake, aggregation,
meniscus forces, or wall-corrected drag. At the cylindrical wall positions
are reflected, which prevents a silent escape but is not a hydrodynamic wall
model. Refraction through glass and liquid is deliberately simplified to a
fixed apparent contrast and Gaussian PSF in this first stage.
illumination is "back" or "side". A fixed seed determines
object positions, sensor noise, and scratches. The direct return is
(frames, truth); truth contains a row table with object type, frame,
projected positions, physical positions and visibility, plus angular-speed
truth. The ledger adapter returns only the video frames.
The rendered outline is a display-only 2R-like profile, not a metrology
calibration. Its public dimensional source is ISO 8362-1:2018(E), Table 1
(2R: 16 mm body, 13 mm finish, 35 mm overall height, 8 mm finish height),
previewed at
https://cdn.standards.iteh.ai/samples/74398/343407bc7b564f6184bfa0a9decede14/ISO-8362-1-2018.pdf.
An independent public 2R product listing confirms the 16 mm body and 35 mm
overall height at
https://www.westpharma.com/es-es/products/vial-containment-solutions/vials/nuova-ompi-sg-ez-fill-glass-vials-sterile-3-8-10.
描画外形は計測校正ではなく、公開 ISO 8362-1:2018(E) Table 1 の 2R 比率を
使う表示モデルである。独立した公開製品寸法も上記 URL で確認する。
Raises ValueError for nonphysical dimensions, an unknown illumination,
or a nonintegral object count.
py -3.11 examples/poc_vial_particle_pod.pyvideo を入力に取れる)synth)—
Provenance: vialops.py — PHARMA operator registry. この per-op ノートは tools/opdocs.py md が自動生成(手編集しない)。
© 2026 Kazufumi Furuse — Fullseye operator documentation. Licensed under Apache-2.0.